35kV Class And Below Dry-Type Dual-Split Transformer

Features :
Customizable
Voltage adjustment tap
Stainless steel hardware
High-grade silicon-steel core
Copper or aluminum windings available
Low loss, low noise, low partial discharge, high efficiency, high reliability
Main Overview:

The dry-type dual-split transformer is a special type of transformer characterized by having two independent low-voltage windings, which can supply power to different loads respectively. The dual independent secondary winding design achieves fully enclosed insulation through high-precision epoxy resin vacuum casting. The rated voltage covers 10kV to 35kV, with a capacity range of 630kVA to 16MVA. It offers protection levels up to IP54 and Class F/H temperature withstand. Specifically designed for renewable energy applications such as PV, wind power, and energy storage, as well as data centers, semiconductor plants, and hospitals. When a fault occurs in one load circuit, the other split winding continues to supply power, ensuring zero interruption to critical loads.

Meaning of Model Number:

Meaning of Model Number

S

C

F

(B)

-

/

 

Three-phase

Epoxy resin cast type

Split

Low voltage foil wound coils can be used

Performance level code

 

Rated capacity kVA

 

Voltage class kV

Performance characteristics:

Dual Power Supply Safety Guarantee: When a fault occurs in one load circuit, the other split winding continues to supply power. One transformer, dual supply – the architecture saves 50% space and 25% equipment procurement cost.

Precise Electromagnetic Balance: The symmetry deviation of the split windings is <2%, meeting the ampere-turn balance requirement. This solves the problem of large dimensional deviation between the upper and lower windings.

Compact Structure Design: The footprint is reduced by 45% compared to two independent transformers. The internal ventilation of the protective enclosure is optimized, reducing hot-spot temperature rise.

Main performance parameters of SCF(B)12 dry-type dual-split transformer:

Model

Rated capacity

(kVA)

Vector group

Voltage combination(kV)

No-load loss

(W)

Load loss(W)120℃

(F)

Impedance voltage

(%)

High voltage

Tapping range

Low voltage

SCF(B)12-1000

1000

Dyn11

35 36 37 38.5

±2x2.5% ±5%

0.4

1700

10400

6~14

SCF(B)12-1250

1250

2000

12700

SCF(B)12-1600

1600

2300

15400

SCF(B)12-2000

2000

2700

18200

SCF(B)12-2500

2500

3200

21800

SCF(B)12-3000

3000

3900

24000

SCF(B)12-3150

3150

4300

24500

SCF(B)12-4000

4000

5000

29400

SCF(B)12-4500

4500

5400

32300

SCF(B)12-5000

5000

6000

34900

SCF(B)12-6300

6300

7100

40800

SCF(B)12-8000

8000

8500

49200

SCF(B)12-10000

10000

10200

57900

 