On-Load Tap-Changing Dry-Type Transformer
SCZ series on‑load tap‑changing dry‑type transformer adopts epoxy resin vacuum cast insulation, integrated with high‑performance vacuum on‑load tap‑changer. It realizes continuous voltage regulation without power cut under load.
Rated voltage covers 10kV‑35kV, capacity ranges from 800kVA up to 25MVA. It features wide regulation range and fast response speed. This transformer is specially developed for occasions demanding high‑stability power supply, such as new‑energy grid‑connection points, urban substations and heavy‑duty industrial sites. The all‑in‑one layout of transformer body and tap‑changer cabinet reduces field‑assembly workload and shortens construction period. Oil‑free dry‑type structure brings outstanding fire‑safety performance for indoor substation deployment.
|
Meaning of Model Number |
S |
C |
Z |
□ |
- |
□ |
/ |
□ |
|
|
Three-phase |
Epoxy resin cast type |
On-load regulated voltage |
Performance level code |
|
Rated capacity kVA |
|
Voltage class kV |
1. Live Voltage Regulation and Uninterrupted Power Supply
Equipped with a reliable vacuum live tap changer. It enables rapid tap switching while the system is energized, maintaining a stable output voltage in response to grid voltage fluctuations, making it ideal for new energy grid-connection applications.
2. High-Quality Epoxy Resin Vacuum-Cast Windings
Utilizes an advanced epoxy resin vacuum-casting process. Features excellent partial discharge performance, high mechanical strength, and resistance to cracking, dust, and moisture, making it suitable for complex indoor operating environments.
3. Optimized Insulation and Cooling Design
A rational longitudinal insulation structure ensures exceptional dielectric performance. An optimized forced air-cooling system effectively controls winding temperature rise and extends service life.
4. Integrated, Compact Layout
The transformer body and on-load tap changer control cabinet are pre-integrated at the factory. This simplifies on-site installation and wiring, shortening the project construction cycle.
5. Comprehensive Intelligent Monitoring and Protection
Features a multi-channel winding temperature detection system, automatic fan control, over-temperature alarms, and trip functions. Remote signal interfaces are provided for easy connection to SCADA systems.
6. High Safety and Low Maintenance
The oil-free, dry-type design eliminates fire hazards and the risk of oil leaks. It features fire- and explosion-proof characteristics, making it suitable for indoor substations. Copper windings are standard; aluminum windings are also available for cost-optimized projects.
|
Model |
Rated capacity (kVA) |
Vector group |
Voltage combination(kV) |
No-load loss (W) |
Load loss(W)120℃ (F) |
No-load current (%) |
Impedance voltage (%) |
||
|
High voltage |
Tapping range |
Low voltage |
|||||||
|
SCZ11-2000 |
2000 |
Dyn11 Yyn0 |
35 36 37 38.5 |
±4x2.5% |
6 6.3 10 10.5 11 |
4050 |
19000 |
0.65 |
7 |
|
SCZ11-2500 |
2500 |
4690 |
22600 |
0.65 |
|||||
|
SCZ11-3150 |
3150 |
5670 |
25400 |
0.6 |
8 |
||||
|
SCZ11-4000 |
4000 |
6640 |
30400 |
0.6 |
|||||
|
SCZ11-5000 |
5000 |
7850 |
36100 |
0.5 |
|||||
|
SCZ11-6300 |
6300 |
9270 |
41800 |
0.5 |
|||||
|
SCZ11-8000 |
8000 |
10600 |
47500 |
0.45 |
9 |
||||
|
SCZ11-10000 |
10000 |
12100 |
57100 |
0.45 |
|||||
|
SCZ11-12500 |
12500 |
14700 |
66500 |
0.35 |
|||||
|
SCZ11-16000 |
16000 |
18100 |
78200 |
0.35 |
|||||
|
SCZ11-20000 |
20000 |
21400 |
88000 |
0.3 |
10 |
||||
|
SCZ11-25000 |
25000 |
25200 |
104000 |
0.3 |
|||||