S13-M Oil-Immersed Distribution Transformer
The S13-M series is a high-efficiency, fully sealed oil-immersed distribution transformer upgraded from the S11 series.
By adopting improved silicon-steel materials and an optimized core-and-coil structure, the transformer is designed to reduce no-load losses and operating noise while maintaining reliable electrical performance.
The fully sealed construction helps prevent air and moisture ingress, reducing oil oxidation and supporting maintenance-free operation. With a compact and reliable design, the S13-M series is suitable for urban and rural distribution networks as well as industrial and commercial power supply applications.
01. Upgraded Core & Coil Design
Improved silicon-steel materials and an optimized core-and-coil structure help reduce no-load losses and operating noise.
02. Fully Sealed Construction
The fully sealed oil-immersed structure helps prevent air and moisture ingress and reduces oil oxidation.
03. Maintenance-Free Operation
The sealed design helps minimize routine maintenance requirements under normal operating conditions.
04. Lower Operating Noise
The optimized transformer structure reduces operating noise, with noise levels stated to be approximately 20% lower than conventional distribution transformers.
05. Flexible Configuration
Rated capacity and voltage configuration can be adjusted according to distribution network and project requirements.
06. Copper or Aluminum Windings
Copper or aluminum winding options are available according to the product configuration and customer requirements.
07. Outdoor-Ready Hardware
Stainless steel hardware helps support long-term outdoor operation.
08. Reliable Electrical Performance
The transformer is designed for low losses, low partial discharge, high efficiency and reliable long-term operation.
|
Model |
Rated capacity (kVA) |
Vector group |
Voltage combination(kV) |
No-load loss (W) |
Dy Load loss(W)75℃ (A) |
No-load current (%) |
Impedance voltage (%) |
||
|
High voltage |
Tapping range |
Low voltage |
|||||||
|
S13-M-30 |
30 |
Dyn11 |
10 |
±2x2.5% |
0.4 |
80 |
630 |
1.5 |
4 |
|
S13-M-50 |
50 |
100 |
910 |
1.3 |
|||||
|
S13-M-63 |
63 |
110 |
1090 |
1.2 |
|||||
|
S13-M-80 |
80 |
130 |
1310 |
1.2 |
|||||
|
S13-M-100 |
100 |
150 |
1580 |
1.1 |
|||||
|
S13-M-125 |
125 |
170 |
1890 |
1.1 |
|||||
|
S13-M-160 |
160 |
200 |
2310 |
1 |
|||||
|
S13-M-200 |
200 |
240 |
2730 |
1 |
|||||
|
S13-M-250 |
250 |
290 |
3200 |
0.9 |
|||||
|
S13-M-315 |
315 |
340 |
3830 |
0.9 |
|||||
|
S13-M-400 |
400 |
410 |
4520 |
0.8 |
|||||
|
S13-M-500 |
500 |
480 |
5410 |
0.8 |
|||||
|
S13-M-630 |
630 |
570 |
6200 |
0.6 |
4.5 |
||||
|
S13-M-800 |
800 |
700 |
7500 |
0.6 |
|||||
|
S13-M-1000 |
1000 |
830 |
10300 |
0.6 |
|||||
|
S13-M-1250 |
1250 |
970 |
12000 |
0.5 |
|||||
|
S13-M-1600 |
1600 |
1170 |
14500 |
0.5 |
|||||
|
S13-M-2000 |
2000 |
1360 |
18300 |
0.4 |
5 |
||||
|
S13-M-2500 |
2500 |
1600 |
21200 |
0.4 |
|||||
|
Meaning of Model Number |
S |
M |
(B) |
13 |
- |
□ |
/ |
□ |
|
|
Three-phase |
Fully sealed |
For capacity of 400kVA and above, low-voltage foil wound coils can be used. |
Performance level code |
|
Rated capacity kVA |
|
Voltage class kV |
The S13-M series uses a fully sealed oil-immersed structure designed to isolate the transformer oil from external air and moisture.
By reducing moisture ingress and oil oxidation, the sealed structure helps maintain insulation performance and supports maintenance-free operation under normal service conditions.
Urban Power Distribution
For urban distribution networks and infrastructure power supply.
Rural Power Distribution
Suitable for rural distribution networks and electrification projects.
Industrial Power Supply
For factories and industrial electrical systems requiring reliable distribution power.
Commercial Power Supply
Suitable for commercial buildings and other low-voltage distribution applications.
What is an S13-M transformer?
The S13-M is a high-efficiency, fully sealed oil-immersed distribution transformer upgraded from the S11 series.
What is the capacity range?
The current S13-M product series covers rated capacities from 30 kVA to 2,500 kVA.
What is the standard voltage configuration?
The listed two-winding series uses 10 kV high voltage and 0.4 kV low voltage.
Is the S13-M fully sealed?
Yes. The series uses a fully sealed oil-immersed structure designed to reduce air and moisture ingress.
Is the S13-M maintenance-free?
The fully sealed design supports maintenance-free operation under normal service conditions.
Is the S13-M quieter than conventional distribution transformers?
The current product description states that its noise level is approximately 20% lower on average than conventional distribution transformers.
Are copper and aluminum windings available?
Yes. Copper or aluminum winding configurations can be provided according to the product and project requirements.
Can the transformer be customized?
Yes. Capacity, voltage, cooling mode and winding configuration can be customized according to project requirements.
What standards does the S13-M comply with?
The current product page states compliance with IEC and GB standards.