HomeProductsHigh-Voltage Switchgear SeriesKYN28A‑12 Indoor Draw‑out Armored AC Metal‑Enclosed High‑Voltage Switchgear, 12kV

KYN28A‑12 Indoor Draw‑out Armored AC Metal‑Enclosed High‑Voltage Switchgear, 12kV

Features :
Indoor removable / draw‑out vacuum circuit‑breaker cabinet
Complete 5‑interlock anti‑misoperation safety protection system
Compact cabinet layout, space‑saving design
Optional VS1, VN2 mid‑mounted vacuum circuit breaker
Heat‑shrinkable / epoxy‑coated bus‑bar insulation
Wide rated‑current range: 630A‑3150A
High short‑circuit withstand performance
Custom‑built cabinet configuration available
Compliant with IEC & GB international standards
Product Overview:

KYN28A‑12 indoor AC armored removable metal‑enclosed switchgear is suitable for three‑phase AC power systems with rated voltage of 12kV and rated frequency of 50Hz, for receiving and distributing electrical energy, as well as for controlling, protecting and monitoring circuits.

This product complies with the requirements of GB3906 "AC Metal‑enclosed Switchgear for Rated Voltages of 3.6kV to 40.5kV", GB/T11022 "Common Technical Requirements for High‑voltage Switchgear and Control Equipment", IEC60298 "AC Metal‑enclosed Switchgear and Controlgear for Rated Voltages Above 1kV and Up to 52kV", and DL/T404 "Technical Specification for Indoor AC High‑voltage Switchgear".

Full anti‑misoperation interlock functions are equipped: preventing moving‑cart operation under load, forbidding breaker closing while earthing switch is on, avoiding earthing‑switch closing on live circuits and blocking unauthorized access to live compartments. With compact layout, easy‑operation design and stable performance, it delivers high‑safety indoor power‑distribution.

Meaning of Model Number
Meaning of Model Number K Y N 28 12 Z
Explanation Armored metal‑clad cabinet Removable / draw‑out type Indoor installation Design serial number Separator Rated voltage(kV) Vacuum circuit‑breaker
Service Conditions
  • Ambient air temperature: Max 40℃, Min ‑15℃
  • Relative humidity: Daily average ≤95%, daily average water‑vapour pressure ≤2.2kPa; Monthly average ≤90%, monthly average water‑vapour pressure ≤1.8kPa
  • Altitude: ≤1000m above sea‑level
  • Earthquake intensity: ≤Grade 8
  • Surrounding air: No obvious pollution by corrosive or flammable gas, water vapour etc.
  • No violent vibration at installation site
  • For operation environments exceeding GB3906 standard conditions, special technical solutions can be negotiated between our factory and buyers
Main Technical Parameters
Item Unit Parameter
Rated Voltage kV 3.6, 7.2, 12
Rated Frequency Hz 50
Rated Current of Circuit Breaker A 630, 1250, 1600, 2000, 2500, 3150
Rated Current of Switchgear A 630, 1250, 1600, 2000, 2500, 3150
Rated Short‑time Withstand Current (4s) kA 20, 25, 31.5, 40
Rated Peak Withstand Current kA 50, 63, 80, 100
Rated Short‑circuit Breaking Current kA 20, 25, 31.5, 40
Rated Short‑circuit Making Current (peak) kA 50, 63, 80, 100
1min Power‑frequency Withstand Voltage (phase‑to‑earth / between phases) kV 24, 32, 42
1min Power‑frequency Withstand Voltage (across isolating gap) kV 28, 32, 42
Lightning‑impulse Withstand Voltage (phase‑to‑earth / between phases) kV 40, 60, 75
Lightning‑impulse Withstand Voltage (across isolating gap) kV 46, 70, 85
Protection Degree   Shell IP4X; Between compartments & when breaker‑compartment door open: IP2X